Categories

Steps to maintain the reverse osmosis system

Views : 16
Update time : 2024-04-28 17:36:42
 The procedure for maintaining the reverse osmosis system is as follows

1, record daily water quality monitoring and equipment control parameters, such as abnormal to deal with in time. Periodically check and record key parameters such as water conductivity, each pressure point and the amount of water in and out every day.

2, fixed stationary cycle time to the salt box plus regenerant, according to the actual situation and water production rate to determine the regeneration time. This is usually done every 3-4 days.

3. Replace the filter element of the multi-media filter regularly, generally every 3-6 months.

4, often clean the equipment to ensure that it is cleaned.

5. Regularly maintain whether there is water leakage in the pipeline. If water seepage is found, it should be treated in time.

should ensure that the system can normal power supply system. In special cases, if the power or water is cut off, it is necessary to re-plan the duration of the machine, especially the reconstruction time after the power failure. It is strictly prohibited for non-staff to touch the button of the motor control part and the gate valve of the pipeline part, so as to avoid the operation error endangering the normal operation of the machine and equipment.

In case of emergency, if the equipment is powered off or the main valve, membrane and other parts of the production of pure water are damaged, and it is impossible to produce pure water, we can open the softened water treatment gate valve and use the softened water treatment normally to ensure the normal operation of the tap water equipment. However, this method should be operated according to the actual requirements of the tap water machine.

When serious water seepage occurs in the equipment, the water seepage power switch should be turned off immediately, and power off, and tell the service provider to deal with it in time.

2. In the water treatment process, if the post-film barometer indicates that it exceeds 1.5Mpa, the resistivity exceeds 15us/cm or the water body exceeds the standard scope, it should be timely replaced with epoxy resin, film, activated carbon and other consumables.

Because consumables such as quartz sand, activated carbon, and softened resins are all granular chemicals, they are easy to produce porous materials after deposition, which brings a living environment for long-term breeding of microbial strains. At the same time, activated carbon and softened resin have a certain adsorption contrast, and the filtration effect will decrease after long-term use. When the reengineering cleaning can not meet the preliminary treatment effect, it is necessary to replace this consumable to ensure that the water body of the ro reverse osmosis membrane is fed.

In the case that most standards can be met, the service life of quartz sand is 10-24 months, the service life of activated carbon is 10-12 months, the service life of epoxy resin is 10-12 months, the service life of high-precision filter element is 3-6 months, and the service life of ro reverse osmosis membrane is about 12 months.

Resin regeneration cycle time: In a conventional environment, the resin regeneration cycle is 1 to 3 days.
NEWSLETTER